Quantcast
Channel: VMware Communities : All Content - All Communities
Viewing all 176760 articles
Browse latest View live

LUN does not show correct size after extend

$
0
0

Hi,

 

we are running cluster of 4 hosts, connected via FC to Lenovo Storage V3700 V2. We extended one of the LUNs from 16 to 20TB, but vCenter still shows 16TB size. When we go to a host - configure - storage devices, the correct size is shown (20TB), but Datastores shows 16TB. We found this article VMware Knowledge Base and upgraded the hosts to " 6.5.0, 15256549" (they were ESXi 6.5. Patch 01, build 5146846), but nothing changed. The current version of vSphere web client is "Version 6.5.0.32000 Build 15259038".

 

Anyone having same or similar issue?

 

Thanks in advance.


vSphere 7, unable to stop syslog service.

$
0
0

Has anyone else experienced this issue?

 

I was trying to stop syslog from the vCenter GUI and the ESXi GUI but I am getting the following error,  I am able to stop / start the NTP service just fine, so it really appears to be related to the syslog service.

 

this occurs on all my hosts running vCenter / ESXi 7.

 

vCenter7.0.1 Build:16858589

 

 

I sshed to the host and checked the service...

 

 

[root@ESX1:~] ps -Cc|grep vmsyslogd

17375454  17375454  grep                  grep vmsyslogd

17275879  17275879  vmsyslogd             /bin/python /usr/lib/vmware/vmsyslog/bin/vmsyslogd.pyc start

17275878  17275878  wdog-17275879         /bin/python /usr/lib/vmware/vmsyslog/bin/vmsyslogd.pyc start

 

 

Looking at the vCenter logs

 

2020-10-16T10:56:45.956333+00:00 vcsavpxd-main-- - 2020-10-16T10:56:45.956Z info vpxd[19461] [Originator@6876 sub=Default opID=kg76l8h1-24611-auto-izp-h5:70009269-56] [VpxLRO] -- ERROR task-14509 -- serviceSystem-15827 -- vim.host.ServiceSystem.stop: vmodl.fault.InvalidArgument:\n--> Result:\n--> (vmodl.fault.InvalidArgument) {\n-->    faultCause = (vmodl.MethodFault) null, \n-->    faultMessage = <unset>, \n-->    invalidProperty = "id"\n-->    msg = "Received SOAP response fault from [<cs p:00007f3d705d2e40, TCP:192.168.16.132:443>]: stop\n--> Received SOAP response fault from [<cs p:000000e3585b26a0, TCP:localhost:8307>]: stop\n--> A specified parameter was not correct: id"\n--> }\n--> Args:\n--> \n--> Arg id:\n--> "vmsyslogd"

 

 

 

[root@ESX1:~] /usr/lib/vmware/vmsyslog/bin/vmsyslogd staus

Watchdog fork failed 28 (No space left on device)

 

 

 

[root@ESX1:~] df -l

Filesystem         Bytes          Used    Available Use% Mounted on

VMFS-5      525059751936   64702382080 460357369856  12% /vmfs/volumes/ESX1-SSD1

VMFS-L        6442450944    1715470336   4726980608  27% /vmfs/volumes/LOCKER-5f12e0b8-3d2dfc46-023e-ac1f6b781582

vfat           524009472     189685760    334323712  36% /vmfs/volumes/BOOTBANK2

vfat           524009472     189874176    334135296  36% /vmfs/volumes/BOOTBANK1

vsan       3000628174848 2257722143988 742906030860  75% /vmfs/volumes/vSAN_HZ-CL01

 

 

[root@ESX1:~] vdf -h

Tardisk                  Space      Used

vmx.v00                   116M      116M

vim.v00                   139M      139M

tpm.v00                    24K       22K

sb.v00                    171M      171M

s.v00                      68M       68M

bnxtnet.v00               688K      685K

bnxtroce.v00              324K      323K

brcmfcoe.v00                2M        2M

brcmnvme.v00              124K      123K

elxiscsi.v00              548K      546K

elxnet.v00                636K      635K

i40en.v00                 604K      602K

i40iwn.v00                484K      480K

iavmd.v00                 196K      195K

igbn.v00                  320K      319K

iser.v00                  260K      259K

ixgben.v00                524K      520K

lpfc.v00                    2M        2M

lpnic.v00                 636K      635K

lsi_mr3.v00               348K      344K

lsi_msgp.v00              484K      482K

lsi_msgp.v01              552K      549K

lsi_msgp.v02              512K      511K

mtip32xx.v00              256K      252K

ne1000.v00                636K      633K

nenic.v00                 264K      261K

nfnic.v00                 576K      573K

nhpsa.v00                 612K      611K

nmlx4_co.v00              784K      781K

nmlx4_en.v00              732K      730K

nmlx4_rd.v00              340K      338K

nmlx5_co.v00                1M        1M

nmlx5_rd.v00              292K      288K

ntg3.v00                  116K      115K

nvme_pci.v00              120K      117K

nvmerdma.v00              168K      164K

nvmxnet3.v00              196K      193K

nvmxnet3.v01              172K      168K

pvscsi.v00                124K      121K

qcnic.v00                 300K      297K

qedentv.v00                 3M        3M

qedrntv.v00                 2M        2M

qfle3.v00                   2M        2M

qfle3f.v00                  1M        1M

qfle3i.v00                368K      367K

qflge.v00                 500K      498K

rste.v00                  828K      825K

sfvmk.v00                 648K      647K

smartpqi.v00              364K      362K

vmkata.v00                204K      202K

vmkfcoe.v00              1008K     1006K

vmkusb.v00                  1M        1M

vmw_ahci.v00              236K      234K

crx.v00                    12M       12M

elx_esx_.v00                2M        2M

btldr.v00                   1M        1M

esx_dvfi.v00              488K      484K

esx_nsxv.v00               35M       35M

esx_ui.v00                 14M       14M

esxupdt.v00                 1M        1M

tpmesxup.v00               12K       11K

weaselin.v00                2M        2M

loadesx.v00                56K       53K

lsuv2_hp.v00               72K       70K

lsuv2_in.v00               28K       26K

lsuv2_ls.v00                1M        1M

lsuv2_nv.v00               16K       13K

lsuv2_oe.v00               16K       13K

lsuv2_oe.v01               16K       13K

lsuv2_oe.v02               16K       13K

lsuv2_sm.v00               56K       54K

native_m.v00                2M        2M

qlnative.v00                2M        2M

vdfs.v00                   12M       12M

vmware_e.v00              188K      187K

vsan.v00                   46M       46M

vsanheal.v00                7M        7M

vsanmgmt.v00               21M       21M

xorg.v00                    3M        3M

state.tgz                  64K       60K

vmware_f.v00               31M       31M

imgdb.tgz                   1M        1M

-----

Ramdisk                   Size      Used Available Use% Mounted on

root                       32M        2M       29M   8% --

etc                        28M      808K       27M   2% --

opt                        32M        0B       32M   0% --

var                        48M      828K       47M   1% --

tmp                       256M        9M      246M   3% --

iofilters                  32M        0B       32M   0% --

shm                      1024M        0B     1024M   0% --

crx                      1024M        0B     1024M   0% --

configstore                32M       64K       31M   0% --

configstorebkp             32M       64K       31M   0% --

vsantraces                300M      217M       82M  72% --

hostdstats                553M        7M      545M   1% --

 

[root@ESX1:~] stat -f /

  File: "/"

    ID: 100000000 Namelen: 127     Type: visorfs

Block size: 4096

Blocks: Total: 1055831    Free: 807322     Available: 807322

Inodes: Total: 655360     Free: 647863

 

 

Very strange, anyone else running 7 that doesn't mind trying?

iSCSI and vSAN sharing same physical interfaces - 25Gbit

$
0
0

Hello all,

 

I will have to share the same physical nics between vSAN and iSCSI.

 

On my infrastructure, vSAN is using vmic0 as active and vmnic1 as standby.

I need to configure iSCSI to connect to a storage system and  I will need to use the same physical interfaces. The target (4 ip addresses) and the initiators will be on the same network.

 

My question is how can I configure the iSCSI to grant that vSAN and iSCSI aren't using the same interface?

 

Option 1:

- add only one vmkernel to iSCSI and put vmnic0 on standby and vmnic 1 as active (because on vSAN vmkernel I have vmic0 active and vmnic1 standby). Can I use this configuration?  will I have redundancy?

 

Option 2:

- if  I create  two vmkernels:

vmkernel- iSCSI1 with vmnic0 active and vmnic1 unused and vmkernel- iSCSI2 with vmnic0 unused and vmnic1 active, one of the vmkernel's will be using at the same time, the same nic as the vSAN, right?

 

What should i do?

 

Thanks.

Regards

NSX-T 3.0 - 100 VRF Lite per T0

$
0
0

Hello all,

After 100 VRF's per T0, it will be need to create other T0 to had more VRF's. With that, for the 2nd T0 I will need to deploy other pair of edge nodes to create other cluster.

My question is:

- For that 2nd T0, can I use the same segments that connect the 1st T0 to ToR A and ToR B, or should I create new segments on other vlan's for that?

 

Thanks.

Regards.

Addin multiple disks on diffrent SCSI controllers via PowerCLI script

$
0
0

I am trying to create a Powercli script for adding additional disks to Sql vms. Scripts runs fine but the disks labels wont create evenly across multiple scsi controllers.

 

Ideally this is what I am trying to get.

 

Hard disk 1  on SCSI 0:1
Hard disk 2  on SCSI 0:2
Hard disk 3  on SCSI 1:1
Hard disk 4  on SCSI 1:2
Hard disk 5  on SCSI 2:1
Hard disk 6  on SCSI 2:2
Hard disk 7  on SCSI 3:1
Hard disk 8  on SCSI 3:2

Hard disk 9  on SCSI 3:3


But this is what I get.


Hard disk 7  on SCSI 0:1
Hard disk 2  on SCSI 0:2
Hard disk 8  on SCSI 1:1
Hard disk 6  on SCSI 1:2
Hard disk 9  on SCSI 2:1
Hard disk 4  on SCSI 2:2
Hard disk 10  on SCSI 3:1
Hard disk 5  on SCSI 3:2

Hard disk 3  on SCSI 3:3

_________________________________________________________________________


Here is my script.

$VMname = Read-Host " Enter the VM hostname"

$D=Read-Host "Enter D drive GB Size"

$E=Read-Host "Enter E drive GB Size"

$SYSTEMDBS1 = Read-Host "Enter SYSTEMDB1 GB Size"

$DATA1 = Read-Host "Enter DATA1 GB Size"

$LOGS1 = Read-Host "Enter LOGS1 GB Size"

$DBA_ADMIN_LOGS1 = Read-Host "Enter DBA_ADMIN_LOGS1 GB Size"

$TEMPDB1 = Read-Host "Enter TEMPDB1 GB Size"

$DBA_ADMIN_DATA1 = Read-Host "Enter DBA_ADMIN_DATA1 GB Size"

$DBAUTILITY = Read-Host "Enter DBAUTILITY GB Size"

 

 

stop-vm -vm $VMname -confirm:$false

Start-sleep -s 5

$VM= get-vm -Name $VMname

 

 

##Adding D and E Drive

New-HardDisk -VM  $VM -CapacityGB  $D -DiskType Flat -StorageFormat Thin

New-HardDisk -VM  $VM -CapacityGB  $E -DiskType Flat -StorageFormat Thin

 

 

foreach ($HardDisk in (1))

{

 

 

$VM | New-HardDisk  -CapacityGB   $SYSTEMDBS1  -DiskType Flat -StorageFormat Thin | New-ScsiController -Type ParaVirtual

##

$hdskToChange = Get-HardDisk -VM $VM -Name "Hard disk 4"

##$VM | Get-HardDisk -Name "Hard Disk 3"

## create a new VirtualMachineConfigSpec, with which to make the change to the VM's disk

$spec = New-Object VMware.Vim.VirtualMachineConfigSpec

## create a new VirtualDeviceConfigSpec

$spec.deviceChange = New-Object VMware.Vim.VirtualDeviceConfigSpec

$spec.deviceChange[0].operation = "edit"

## populate the "device" property with the existing info from the hard disk to change

$spec.deviceChange[0].device = $hdskToChange.ExtensionData

## then, change the second part of the SCSI ID (the UnitNumber)

$spec.deviceChange[0].device.unitNumber = 0

## reconfig the VM with the updated ConfigSpec (VM must be powered off)

$VM.ExtensionData.ReconfigVM_Task($spec)

 

 

Start-Sleep -s 5

New-HardDisk -VM  $VM -CapacityGB  $DATA1 -DiskType Flat -StorageFormat Thin -Controller "SCSI Controller 1"

}

 

## Disks on Controller 2

foreach ($HardDisk in (1))

{

 

$VM | New-HardDisk  -CapacityGB  $LOGS1 -DiskType Flat -StorageFormat Thin | New-ScsiController -Type ParaVirtual

##

$hdskToChange = Get-HardDisk -VM $VM -Name "Hard disk 6"

##$VM | Get-HardDisk -Name "Hard Disk 3"

## create a new VirtualMachineConfigSpec, with which to make the change to the VM's disk

$spec = New-Object VMware.Vim.VirtualMachineConfigSpec

## create a new VirtualDeviceConfigSpec

$spec.deviceChange = New-Object VMware.Vim.VirtualDeviceConfigSpec

$spec.deviceChange[0].operation = "edit"

## populate the "device" property with the existing info from the hard disk to change

$spec.deviceChange[0].device = $hdskToChange.ExtensionData

## then, change the second part of the SCSI ID (the UnitNumber)

$spec.deviceChange[0].device.unitNumber = 0

## reconfig the VM with the updated ConfigSpec (VM must be powered off)

$VM.ExtensionData.ReconfigVM_Task($spec)

 

 

Start-Sleep -s 5

 

 

New-HardDisk -VM  $VM -CapacityGB  $DBA_ADMIN_LOGS1 -DiskType Flat -StorageFormat Thin -Controller "SCSI Controller 2"

}

 

## For Disk on Controller 3

 

foreach ($HardDisk in (1))

{

 

 

$VM | New-HardDisk  -CapacityGB  $TEMPDB1 -DiskType Flat -StorageFormat Thin | New-ScsiController -Type ParaVirtual

##

$hdskToChange = Get-HardDisk -VM $VM -Name "Hard disk 8"

##$VM | Get-HardDisk -Name "Hard Disk 3"

## create a new VirtualMachineConfigSpec, with which to make the change to the VM's disk

$spec = New-Object VMware.Vim.VirtualMachineConfigSpec

## create a new VirtualDeviceConfigSpec

$spec.deviceChange = New-Object VMware.Vim.VirtualDeviceConfigSpec

$spec.deviceChange[0].operation = "edit"

## populate the "device" property with the existing info from the hard disk to change

$spec.deviceChange[0].device = $hdskToChange.ExtensionData

## then, change the second part of the SCSI ID (the UnitNumber)

$spec.deviceChange[0].device.unitNumber = 0

## reconfig the VM with the updated ConfigSpec (VM must be powered off)

$VM.ExtensionData.ReconfigVM_Task($spec)

 

 

Start-Sleep -s 5

 

 

New-HardDisk -VM  $VM -CapacityGB  $DBA_ADMIN_DATA1 -DiskType Flat -StorageFormat Thin -Controller "SCSI Controller 3"

 

 

New-HardDisk -VM  $VM -CapacityGB  $DBAUTILITY -DiskType Flat -StorageFormat Thin -Controller "SCSI Controller 3"

}

 

Start-sleep -s 2

## Start VM

Start-VM -VM $VM -confirm:$false

_____________________________________________________________________________________________________________________



 

Any help would be appreciated.


Thank You



vSphereのエラーログ出力内容の調査方法

$
0
0

vSphereのエラーで出力されている文言で、GoogleやVMwareのナレッジベースで検索してもヒットしないものが多数出力されておりまして、

エラーの理由がわからずにいます。

 

この内容をサポートに問い合わせる以外に、調べる方法(検索ツール、ログの一覧のあるサイト等)、ご存知でしたら

教えていただきたいです。

 

よろしくお願いいたします。

No peer certificate found error

$
0
0

When I connect my esxi host by remote location give no peer certificate found

vRA 7.6 Patch 15 / Custom Form / Conditional Field / No longer working

$
0
0

Hello, 

I just patched our vRA 7.6 to 7.6 Patch 15, not our custom forms are no longer working. It looks like the simple function - visible on condition (e.g. integer > x) is no longer working. 

Has anyone had similar issue?

Gonna roll back the snapshots now..

Regards Kjeld 


The module 'VMware.VimAutomation.Sdk' cannot be installed because the catalog signature in 'VMware.VimAutomation.Sdk.cat' does not match the hash generated from the module.

$
0
0

Unable to install VMware.PowerCLI module getting error as

PS C:\> Install-Module -name vmware.powerCLI -scope CurrentUser -Force -allowclobber
PackageManagement\Install-Package : The module 'VMware.VimAutomation.Sdk' cannot be installed because the catalog
signature in 'VMware.VimAutomation.Sdk.cat' does not match the hash generated from the module.
At C:\Program Files\WindowsPowerShell\Modules\PowerShellGet\1.0.0.1\PSModule.psm1:1661 char:21
+ ...          $null = PackageManagement\Install-Package @PSBoundParameters
+                      ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    + CategoryInfo          : InvalidOperation: (Microsoft.Power....InstallPackage:InstallPackage) [Install-Package],
   Exception
    + FullyQualifiedErrorId : InvalidCatalogSignature,ValidateAndGet-AuthenticodeSignature,Microsoft.PowerShell.Packag
   eManagement.Cmdlets.InstallPackage

My Powershell version details are as below.

PS C:\> $PSVersionTable

Name                           Value
----                           -----
PSVersion                      5.1.14393.0
PSEdition                      Desktop
PSCompatibleVersions           {1.0, 2.0, 3.0, 4.0...}
BuildVersion                   10.0.14393.0
CLRVersion                     4.0.30319.42000
WSManStackVersion              3.0
PSRemotingProtocolVersion      2.3
SerializationVersion           1.1.0.1

macOS - Certificate Based Authentication - App Level or OS Level?

$
0
0

Hello,

We're currently working on revamping our macOS design.

 

While working on it came of course the question of proxies and specifically the authentication onto them.  We have several possibilities for that but it comes along to answer to the following question :

Is it the OS on the Mac that deals with the Certificate Based Authentication aspect or is it each installed app individually ?

 

If it is the latter, for apps like Safari, we're pretty confident this will work properly because of Safari knowing how to handle certificates.

Regarding 3rd party apps, (Bluejean, Adobe Suite...), this is not so sure these would be able to exploit the certificates present in the keychain. Hence the question about CBA being handled by macOS itself or by every single app individually.

 

If anyone knows, that'd be good to know.

 

Thanks,

 

Anton

HA Failover if a Uplink fails

$
0
0

Dear community

 

The environment:

- vCenter 6.7

- two ESXi 6.7 in a HA Cluster

- Network connectivity:

  • Host1 (one Uplink)<-> Switch1 <-> Destination
  • Host2 (one Uplink)<-> Switch2 <-> Destination

- Two VMs

- All VMs are placed on Host1

 

Goal: if Switch1 or the Uplink of Host1 to Switch1 fails, failover of all VMs would be happened to Host2 to restore the connectivity.

 

How can it be done? With HA or Fault Tolerance?

 

Thank you.

How can I Detach my Linux's host interface card enps02 to my VM

$
0
0

Hello Community,

 

Greetings to the Community, Veterans and Noobs of VMware. Please kindly help look into this major issue I'm having.

 

I have a Linux (Ubuntu) machine running a VMware Workstation Pro (trial version). I'm running a firewall device in this VM. I want the VM itself to use a dedicated enps02(/eth0) from my host so that I can configure it (the enps02 interface) as the gateway interface for my Firewall. This is desired to allow internet on the host ONLY through my firewall. Thanks, I sincerely hope for a resolution/idea.

join 2 private networks together into single network between two VMW hosts

$
0
0

Hello guys, I have the following:

1 Host OS: I run there 'Main VM' without internet and 'VPN VM' which seeds (ICS) its VPN connection to the 'Main VM' via vmnet5 adapter (Host-only network, Connect a host is unchecked).

2 Host OS: 'Main VM-2' without internet connection. I would like to join into vmnet5, which is managed by VMW on 1st Host.

 

Both VMV hosts connected into the same wifi network.

Could anyone suggest the most convenient approach? I imagine the solution could be pretty damn easy, but it could be also running a dedicated VM to create bridge, use local VPN, use direct ethernet cable or 2 wifi adapters to create private link. I know only the headlines of these methods but haven't tried anything. Please advise.

ESXI 6.5 GPU Passthrough Quadro Host Rebooting

$
0
0

Hi All,

 

We are trying to get lab environment to test GPU Roughcast to VM's working before going live.

 

I have built a HP DL380 G8 server which is fully up to date with bios patches/firmware etc. I have installed ESXI 6.5.0 as the host OS and under this we have a Windows VM running windows 10 fully up to date inc anniversary update.

 

I have created a pass-through for the Nvidia Quadro K2200 graphics card installed on the server and all is working fine from a VM point of view it sees the card all drives installed and works perfectly for our use.

 

The issue I have is if the VM runs for a few days and then we reboot (long term plan is scheduled reboots at night). The host goes into a complete panic and reboot's itself before the VM has even had a chance to shutdown obviously something is not right with the config.

 

I have done lots of research and have tried playing with various settings etc to try and make it stable for reboots but cannot seem to make it work. I have tried 6 initially and then went to 6.5 off the back of a forum post regarding instability on v6 which I did see during setup not just at reboot stage however 6.5 seems much better other than reboot.

 

Really after any advice from anyone which has tried to do the same on things for me to check.

 

Log files are not really giving me much around the reboot time it's like it simply stops dead.

 

I have passed the audio device through to the VM however on 6.5 it looks like you have to do this as it is a dependent (which was different from 6.0).

 

we are looking to try and use this in production come January next year so would love to iron out the kinks before we shell out for a live system as I cannot have it rebooting like this when live.

 

few forum posts suggest going back to 5.5 with the latest updates as this became alot more stable and win 10 is still supported as an OS.

 

I am willing to send log files etc to try and help solve the problem.

 

thanks

 

Lee

Problem with VDI Pool

$
0
0

Hello,

we have a weird problem with one of our VDI Pool's spreading from a week now 5 machines affected form 29.

We have this Popup with a flashing screen (error2 attachment) using some guides here we've managed to "fix" the flashing screen by stopping the "Windows Error Reporting Service".

But after that, we have this message popping up (error attachment)

 

Does anyone had a similar problem?

 

Thanks in advance for your help.

 

 

 

 

Soft Used:

VMWare Horizon 7.7.0 build-11038474

Agent 7.5.0-8584427

WIndows 10 LTSB 1607 10.0.14393.3930


Please tell me how to research about contents of error log.

$
0
0

I confirmed error log by vSphere.

But there are many logs which aren’t applicable to Google Web Search and VMware Knowledge Base.

So I can't identify the reason of error.

 

 

Is there the way to search it without inquiry to support.

Get VMXNET3 - Network DirectPath I/O Status

$
0
0

Hello Community, is there a way via script to get all VMs that have DirectPath I/O enabled?

2 hosts, 1 v-center + Veeam B&R

$
0
0

Hi community,

 

I currently purchased a 2nd Dell server and have installed Esxi 6.7 on it and soon am planning to install v-center appliance 6.7 as well.

We currently have essentials kit license and one existing Dell server esxi host (6.5) running a few VMs.

I would like some input on the community experience on the best way to set things up so that if one VM fails on my existing host, I will be able to quickly migrate to the 2nd host.

I understand I do not have v-motion with the v-sphere essentials kit, so looking to leverage my existing Veeam B&R platform to help with redundancy and possibly restore VMs to a new location? if that is possible. 

 

Existing dell server host networking is setup like this

- Management Network - vswitch0 - vmnic0 (physical) - 1 gig port (VLAN- 100)

- Production Network - vswitch1 -   vmnic1& vnmic2 (physical) - 1 Gig ports (VLAN-1)

-- 2 x SSDs + 6 x HDDs (two datastores)

 

New dell server host networking not yet setup but it has these physical ports that i could use in any fashion.

 

vmnic0 - 10 gig (teaming)---> thinking of assigning to Prod Network and put on VLAN 1

vmnic1 - 10 gig (teaming)

vnmnic2 - 1 gig (thinking of using this for Mgmt and put on the same MGMT VLAN 100 as my 1st host)

-- 2 x SSDs + 6 x HDDs (two datastores)

 

Question

1. Am i able to achieve some sort of decent redundancy with the above hosts + licenses/budget?

2. Does it make sense to install v-center appliance on the new Dell server, add both hosts? and manage them from the v-center console?

3. Should i update my 1st host to 6.7 first? before adding to the v-center?

4.. will the difference in NIC speeds on both hosts impact anything? in terms of relocating VMs from one host to the other?

5. any other words of wisdom would be appreciated

 

thx

workspace one and intelligence keep user info

$
0
0

can anyone help me with workspace one ? for example i am changing device but my mail is same it shows my mail 2 time but one device how can i change configuration to fix that , then if i need deploy app to user his or her mail show two time ttt.png

 

how can i delete old one or maybe it connected with directory service i need change something there

iSCSI and backup's traffic on the same switch

$
0
0

Hello all,

 

I will have a storage system connected via iSCSI and it will be used only for backup's repository. The iSCSI and backup network will be the same (VLANx). I will have 2 x10Gbit pnics.

 

For iSCSI, i will have iscsi-vmkernel1 assign to vmnic1 and iscsi-vmkernel2 assign to vmnic2, with port binding.

 

My questions are:

1 - for the backup traffic, on the iscsi/backups distributed switch (by the way, should i use standard or distributed?), i will have to create a port group tagged as VLANx, used for backup traffic and a 3rd vmkernel on each host, for that type of traffic, right?

2 - For iscsi traffic i will have a one to one relation, but beside that, for the port group (VLANx), for backup's, i will have the two uplinks active on the teaming and failover options, right?

 

Thanks.

Regards.

Viewing all 176760 articles